The HS1 series low voltage molded circuit breaker is designed to operate
on 50/60Hz AC, with a rated insulation voltage of 1000V, operating voltage
AC400V/230V, and current capacity from 20a to 600A. The breaker provides
reliable protection for electrical power distribution and protection of engines. The
HS1E is also intended for use in measuring boxes since it can interact with the meter
and receive commands, such as query and control. Therefore, the HS1M is a generic
version for multiple uses.

Key Features

Uses and Applications

Environmental Limits

This equipment is engineered to operate effectively at altitudes up to 2000 meters. It is resistant to wind speeds of up to 35 meters per second and can withstand seismic activity up to 8 grades, making it ideal for use in a wide range of outdoor settings.

Temperature & Humidity

Ideal for protDesigned for durability, the system functions smoothly within a temperature range of -10°C to 75°C and can handle relative humidity levels as high as 95%, ensuring consistent operation in both hot and humid environments.ecting industrial machinery and supporting safe, reliable operations in factories, plants, and manufacturing environments.

Safety & Suitability

The device is suitable for environments that are free from fire or explosion risks, and it resists damage from chemical corrosion and heavy vibrations, ensuring long-term safety and operational stability.

Low Voltage Switching Standards

Complies with CEI 1-74906 and 2-74906CEI, covering general rules and circuit breaker requirements for low voltage switching and control systems.

Service Communication Specifications

Follows 10-SMDS-37 guidelines for molded circuit breakers used in low-voltage service communication systems.

Electro-Galvanizing Specifications

Adheres to 336B MTSA standard for zinc electroplating on iron and steel to ensure corrosion resistance and durability in harsh conditions.

Distribution Panel & Cabinet Standards

Meets 20-SMDS-37 and 30-SMDS-37 specifications for molded circuit breakers used in 400A LV panels and PMT distribution cabinets.

LV Molded Case CB (MCCB)

The HS1 series low voltage molded circuit breaker is designed to operate on 50/60Hz AC, with a rated insulation voltage of 1000V, operating voltage AC400V/230V, and current capacity from 20a to 600A. The breaker provides reliable protection for electrical power distribution and protection of
engines. The HS1E is also intended for use in measuring boxes since it can interact with the meter and receive commands, such as query and control. Therefore, the HS1M is a generic version for multiple
uses.

Technical Features

The HS1 series circuit breakers are engineered with advanced safety, performance, and flexibility in mind. Designed to provide complete protection against overload and short circuits, they also feature a secure lock switch and IP30-rated terminal cover to ensure user safety. With high thermal endurance up to 55°C and voltage pulse resistance up to 8kV, these breakers deliver dependable performance in demanding environments. Their compact, arc-free design powered by AD Arc Drive technology, along with the ability to integrate internal accessories, makes them highly adaptable for a wide range of applications.

Advanced Design & Technology
General Features & Safety

This breaker features a thermo-magnetic design that supports high cutting capacity and integrates advanced safety technologies. It includes easily adjustable interior accessories for custom configurations, and uses AD Arc Drive technology to eliminate electrical sparks during operation. The design ensures a consistent form factor across both 630A and 400A models, improving modularity and ease of installation. Additionally, it enhances performance by increasing the cutting capacity relative to unit volume and raising the insulation voltage rating up to Ui=1000V, ensuring robust and efficient electrical protection.

The breaker is designed for infrequent circuit switching and motor starting, offering reliable protection against overload, short circuits, and insulation faults. For enhanced operational safety, it is equipped with a key lock (anti-lock mechanism) and protective end caps at both the entry and exit points. These design elements contribute to an IP30 protection rating, ensuring safe use in various environments. The device also maintains stability at temperatures up to 55°C and withstands voltage shocks of up to 8kV, making it suitable for demanding conditions while allowing for simple and flexible wiring options.

Environmental and Operational Conditions

The HS1 series circuit breakers are engineered with advanced safety, performance, and flexibility in mind. Designed to provide complete protection against overload and short circuits, they also feature a secure lock switch and IP30-rated terminal cover to ensure user safety. With high thermal endurance up to 55°C and voltage pulse resistance up to 8kV, these breakers deliver dependable performance in demanding environments. Their compact, arc-free design powered by AD Arc Drive technology, along with the ability to integrate internal accessories, makes them highly adaptable for a wide range of applications.

01

Altitude & Temperature

Designed to perform reliably at altitudes up to 2000 meters, the equipment can operate in a wide temperature range from -10°C to 75°C, making it suitable for diverse environmental conditions.

02

Wind & Seismic Tolerance

Built to withstand wind speeds up to 35 meters per second and seismic activity up to 8 grades, the system is engineered for resilience in areas prone to extreme weather or ground movement.

03

Humidity Resistance

With a maximum relative humidity tolerance of 95%, the system maintains stable functionality even in high-moisture and tropical environments, ensuring long-term performance.

04

Environmental Suitability

Ideal for clean, hazard-free zones, the product is suited for environments without fire, explosion risks, chemical corrosion, or strong vibrations, ensuring safe and stable operation.